Low Pressure
The key to reaching the medical market is the development of sensors designed for
very low pressure, which much of the industry classifies as under barometric pressure
of 5psi.
In a conventional pressure sensor, a thinner diaphragm results in a device that
can sense smaller amounts of pressure, but the trade-off is that it is much less
linear. Therefore, overall performance (sensitivity and linearity) is not improved
by simply making the diaphragm thinner. A major challenge in designing pressure
sensors is to simultaneously make the linearity curve steeper and extend its linear
range.
One solution for an ultra-sensitive pressure sensor is a thin boss structure created
using silicon micromachining. Broadly speaking, the center boss is etched away to
a thickness that is substantially smaller than the thickness of the substrate. By
reducing the relative size of the boss, the device becomes less sensitive to gravitational
forces, making it more robust. With the thin boss it is possible to obtain higher
sensitivity while maintaining good linearity. Manufacturing the thin-boss structure
is compatible with typical bulk micromachining processes, resulting in minimal cost
increase.
Development of Low-Pressure Sensors
Technology Enablers
- New sensitive MEMS-based boss structures: pressure ranges as low as 0.15psi
- Varied boss designs allow lower pressure ranges to be achieved.

Size reduction
One of the most important advances for medical applications is size reduction. Low
pressure sensors can be used in invasive or external applications, but size will
be an issue since much of the equipment and tools need to be either inserted or
used by hand (for delicate surgery, for example).
SMI has achieved significant size reductions as a result of the implementation of
process enhancements and continuous quality improvements, and as new MEMS-specific
tools have been developed. SMI uses an Alcatel DRIE machine that provides deep,
crisp and smooth cavity walls for high performance.
Development of Ultra-Small Sensors
Technology Enablers
- Highly stable MEMS processes
- New tools and procedures:
- Deep reactive ion etching (DRIE)
- Silicon on Insulator (SOI)
- Expanded materials knowledge
- Improved failure analysis
- Quality programs and certifications
- ISO: 9001
- ISO/TS16949 (automotive industry standards)
Applications
- Absolute pressure measurement inside the body (animal use only)
- Next-generation catheter pressure sensors
- Handheld units for delicate surgery (e.g. ocular, brain, cardiac, dental)

On-chip processing
Selected SMI pressure sensors are integrated, offering calibration, compensation,
amplification, EEPROM and signal processing. The integration occurs via post-processing.
By virtue of their integration these smart single-chip sensors can help OEMs cut
costs and cut down on PCB real estate.
Integration of On-Chip Signal Processing
Technology Enablers
- Advanced CMOS
- Continuous quality improvement
Benefits
- Application-ready for displays, diagnostics, due to on-chip calibration, temperature
compensation, amplification, and signal conditioning
- High accuracy and lower cost
Applications
- Anesthesia
- Respiration monitoring
- Sleep apnea

Harsh Media Pressure Sensing
SMI’s media resistant pressure sensor die offer the ability to stand up to repeat
exposure to harsh environments, including fluids, gases and humidity. Many suppliers
of harsh environment sensors opted to create transducers by encasing them in steel,
which at one point was the only option. OEMs learned to live with it, but the advent
of SMI’s smaller media harsh die offers system designers new options and business
opportunities. SMI’s sensor circuitry is protected by the application of a layer
of glass across the top of the die while providing a backside entry point for the
media.
Harsh Environment Pressure Sensing
Technology Enablers
Benefits
- Allows biofluid and additional chemical compatibility
Applications
- Excess fluid extraction
- Surgery waste fluid evacuation
Small Outline Packaging
A small-outline integrated circuit (SOIC) is an IC package that occupies
an area about 30 - 50% less than an equivalent dual inline package, with a typical
thickness that is 70% less. They are generally available in the same pinouts as
their Dual inline package (DIP) counterparts. The DIP packages have hit real estate
barriers as the lead count has increased in more complex chips
Small Outline Packaging: SO-8, SO-16
Technology Enablers
Benefits
Applications
- Portable medical electronics


Old Style TO-5 and TO-8 Packaging



SO-8 and SO-16 Packages
For more information contact SMI sales at sales@si-micro.com.