Overview

The SMI 5000/ SMI 6000/ SMI 7000 series offers pressure ranges from 0.07 to 2.49 PSI in a gauge, differential or asymmetric differential configuration. This series provides JEDEC standard SOIC-16 package with dual vertical or horizontal porting option. With the dual porting, a reference measurement is possible to minimize errors due to changes in ambient pressure.

Combining the pressure sensor with a signal-conditioning ASIC in a single package simplifies the use of advanced silicon micro-machined pressure sensors. The pressure sensor can be mounted directly on a standard printed circuit board and a high level, calibrated pressure signal can be acquired from the digital interface. This eliminates the need for additional circuitry, such as a compensation network or microcontroller containing a custom correction algorithm.

Benefits

  • Pressure ranges: 0.07 to 2.49 PSI
  • Pressure type: gauge, differential, asymmetric differential
  • 16-bit I2C digital and analog output interface available
  • Total error band: ± 1% FS (digital) and ± 1.5% FS (analog)
  • Pressure calibrated and temperature compensated output
  • Compensated temperature range: -20oC to 85oC

Applications

  • Ventilation devices - CPAP, ventilator, oxygen concentrator and conserver
  • Air and gas flow instrumentation
  • HVACR - ventilation, VAV, filter monitoring
  • Fire pressurization and smoke management
 orange bar
AccuStable logo

The SMI 5000 and SMI 6000 series digital output sensors earned the AccuStable quality label. The AccuStable brand stands for <1% total error band initially and <1% shift during operation over a 10 year lifetime. Qualification is based on 1,000 hours HTOL (High Temperature Operating Life) test at 85°C with 5V.

orange bar
  1. SMI Pressure Sensors Product Overview (English)

TE Connectivity’s (TE) SMI low pressure sensors offer high accuracy and long-term stability in robust compact packages for industrial and medical applications. Watch this video to learn more.

orange bar

LEARN MORE

Related Material

TOPIC RESOURCES
SMI Low Pressure Sensors 
Solution Guide
Ventilator Application Guide
Application Guide
Sleep Mode And Other Low Power Strategies 
Application Note
Trust and Reliability For In-Home Medical Sensors
White Paper
Making HVAC Systems More Efficient and Reliable with Sensors White Paper
Sensors For Medical Ventilators Application Page
orange bar

FAQ

FREQUENTLY ASKED QUESTIONS

What is the proof pressure (maximum pressure to which the device can be taken and still perform within specifications (without loss of accuracy) after returning to the operating pressure range) for the SMI 5000, SMI 6000 and SMI 7000 Series?

The proof pressure for the SMI 7000 (maximum operating pressure range 0.29 PSI) is 1.5 PSI. The SMI 6000 (max operating pressure range 0.79 PSI) has a proof pressure of 4.5 PSI and the SMI 5000 (max operating pressure range 2.49) offers a proof pressure of 12 PSI.

 

What is the burst pressure (pressure where part is permanently damaged) of the SMI 5000, SMI 6000 and SMI 7000 Series?

The burst pressure for the SMI 7000 (maximum operating pressure range 0.29 PSI) is 3 PSI. The SMI 6000 (max operating pressure range 0.79 PSI) has a burst pressure of 6 PSI and the SMI 5000 (max operating pressure range 2.49) offers a burst pressure of 15 PSI.

Features

Please review product documents or contact us for the latest agency approval information.  

Product Type Features

  • Board Level Pressure Sensor Type  Analog Pressure Sensor Modules, Digital Pressure and Altimeter Sensor Modules

  • Board Level Pressure Sensor Style  Differential, Gauge

Configuration Features

  • Tubes  Barb Tube, Tube

Electrical Characteristics

  • Board Level Pressure Sensor Supply Voltage (V) 3, 3.3 – 5, 5

Dimensions

  • Dimensions (mm) 10.26 x 10.31, 19.60 x 10.31, 9 x 6.1

  • Dimensions (in) .35 x .24, .40 x .41, .77 x .41

Usage Conditions

  • Pressure (bar) .019, .054, .172

  • Pressure (psi) .15, .29, .79, 1.45, 2.5

  • Operating Temperature Range (°C) -40 – 105, -20 – 85

  • Operating Temperature Range (°F) -40 – 221, -4 – 185

Operation/Application

  • Output Interface  I²C

  • Pressure (mbar) 5, 10, 20, 54.46, 172.36

  • Pressure (inH2O) 2, 4.01, 5, 8.03, 21.88, 69.26

  • Pressure (mmHG) 3.75, 7.5, 15, 40.85, 129.28

  • Proof Pressure Range  1.5 psi, 12 psi, 15 psi, 4.5 psi

  • Output/Span  10 – 90% Vdc, 16 bit I2C

  • Board Level Pressure Sensor Accuracy  ±1% F.S, ±1.5% F.S

Packaging Features

  • Board Level Pressure Sensor Package  SOIC-16

  • Package Style  Dual Horizontal, Dual Vertical, Single Vertical

Other

  • Sensor Options  Dual Output, No Option

Reference Number

  • TE Internal Number CAT-BLPS0063